contactor configuration ac current sensor BE-500G-1 3pst n.o., 50 amps, 120 vac product specifications construction gasket sealed, vented main contacts: configuration 3pst n.o. voltage (nominal) 120/208 vac, 400 hz current (resistive) 50 amps auxiliary switches: configuration 5-spdt voltage (nominal) 28 vdc current resistive 5 amps inductive 3 amps lamp 2 amps coil data: duty cycle continuous voltage (nominal) 28 vdc pick-up voltage 18 vdc maximum drop-out voltage 1 - 9 vdc coil current @ 28 vdc & +25 c in-rush 3.4 amps maximum hold 1 amp maximum operating temperature -54 c to +71 c life: electrical 50,000 cycles minimum mechanical 100,000 cycles minimum weight 9 lb.4 oz. continuous current 50 amps trip point - three phase 50.5 - 60 amps trip point - single phase 69.0 amps max. catastrophic trip 500 amps 10% features: ? overload current sensing features: ? 3pst n.o. main contacts ? overload current sensing ? 120 vac ? 50 amps ? high reliability ? meets many requirements of mil-r-6106 notes: catalog ( we b d oc o nl y ) dimensions are in inches and dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 5 -04 millimeters unless otherwise reference purposes only. canada: 1-905-470-4425 hong kong: 852-2735-1628 specified. values in brackets specifications subject mexico: 01-800-733-8926 japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-141-810-8967 har t ma n a er o spa ce po wer p ro duct s di men sion s fo r thi s pro du ct a re e xp re ss e d in in ch es . mu l ti pl y val ue s b y 25 .4 f or m ill im et er s . for factory-direct application assistance, con ta ct t h e ha rt ma n p rod uct te am at ( 41 9 ) 52 1 - 95 00 , fa x ( 41 9 ) 5 2 6 - 27 4 9 . ?200 4 by tyco electronics corporation. all rights reserved. ha rt ma n and tyco are trademarks.
|